    Insufflation unit REANIMAT-02-Blend

    The REANIMAT-02-Blend insufflation unit is used for gas mixing and dosing of medical oxygen-air mixtures for non-invasive applications. It is suitable for both stationary and mobile use. Warranty period: 12 months. Country of manufacture: Germany.
    Free shipping
    Guarantee
    Find out the price
    Features
    • Possibility of integrating an aspiration unit.
    • Air humidifier for the flow metering unit.
    • When the flow rate is changed, the oxygen concentration remains unchanged.
    • When the oxygen concentration changes, the selected flow remains constant.
    • Using the on/off switch, the gas supply can be switched off after use. There is no need to close the cylinder valves.
    • The aspirating device is designed with a vacuum control valve and the vacuum value can be read from the manometer. The selected vacuum remains constant after the device is switched off. It does not need to be adjusted again when the device is switched on.
    • When using the second outlet, the sum of both flows can be obtained using the Y-shaped part. In this way, you can use one feed source for coarse adjustment and a second feed source for fine adjustment.
    Characteristics
    • Flow metering: from 0-6 l/min, 0-15 l/min, 0-30 l/min.
    • Oxygen concentration: 21-100%
    • Gas supply stop signal: If the difference between the inlet pressures is 1.5-2 bar
    • Vacuum: Aspiration device 0-0.9 bar
    • Features
    • Characteristics
    • Possibility of integrating an aspiration unit.
    • Air humidifier for the flow metering unit.
    • When the flow rate is changed, the oxygen concentration remains unchanged.
    • When the oxygen concentration changes, the selected flow remains constant.
    • Using the on/off switch, the gas supply can be switched off after use. There is no need to close the cylinder valves.
    • The aspirating device is designed with a vacuum control valve and the vacuum value can be read from the manometer. The selected vacuum remains constant after the device is switched off. It does not need to be adjusted again when the device is switched on.
    • When using the second outlet, the sum of both flows can be obtained using the Y-shaped part. In this way, you can use one feed source for coarse adjustment and a second feed source for fine adjustment.
    • Flow metering: from 0-6 l/min, 0-15 l/min, 0-30 l/min.
    • Oxygen concentration: 21-100%
    • Gas supply stop signal: If the difference between the inlet pressures is 1.5-2 bar
    • Vacuum: Aspiration device 0-0.9 bar